CIBANO 500 PTM User Manual
108 OMICRON
Note: Click More information
to open a diagram explaining the characteristics described in the table.
Note: Click More information
to open a diagram explaining the characteristics described in the table.
Table 15-5: Contact travel
1
1. Only available if testing with the CB TN3 modules
dmin dmax
Total travel, TT
Minimum distance of the contact
travel
Maximum distance of the contact
travel
Over-travel (Trip), OT
Over-travel (Close), OT
Rebound (Trip), RB
Rebound (Close), RB
Contact wipe, CW
Add velocity zone Click Add velocity zone to define a velocity zone for assessment of the
contact travel velocity
(see 15.4 "Velocity zones" on page 113).
Table 15-6: Auxiliary contacts: Trip operation
tmin tmax
Switching time
(a-type), t
switch,a
Minimum operating time of auxiliary
contacts
Maximum operating time of auxiliary
contacts
Diff. to main
(a-type), Δt
a
Switching time
(b-type), t
switch,b
Diff. to main
(b-type), Δt
b
Switching time
(wiper), t
switch,w
Duration
(wiper), Δt
w