17.2.4 Test group execution
Primary Test Manager provides you with a powerful capability for executing test groups. For information
on grouping tests in test groups, see 7.5.2 "Group tests" on page 67. After you set the hardware
configuration of the test set and the test group settings, you can execute all tests of the test group
automatically by clicking the Start all button.
To execute a test group:
1. Group tests in a test group (see 7.5.2 "Group tests" on page 67).
2. Connect the test object to CIBANO 500.
3. In Primary Test Manager, open the test group you want to execute.
4. In the Hardware configuration area, set the hardware configuration and check whether Primary
Test Manager recognized all connected CB MC2 modules. For the hardware configuration options of
CIBANO 500 and the CB MC2 module, see Table 17-38: "Hardware configuration options of
CIBANO 500" on page 179 and Table 17-39: "Hardware configuration options of the CB MC2
module" on page 180.
Figure 17-20: Hardware configuration of the test set for a test group