CIBANO 500 PTM User Manual
300 OMICRON
5. On the navigation bar, click Upgrade, and then click Select file.
Figure 20-3: Upgrading the CIBANO 500 embedded software
6. In the ChooseFiletoUpload window, browse to the upload file. You can find the upload file:
•On the Primary Test Manager DVD at
.\_EmbeddedSoftware\Cibano500\embeddedImage.tar
On the hard disk of your computer at
C:\Program Files (x86)\Common Files\OMICRON\UpgradeImages\CHIMERA\
embeddedImage.tar
7. On the device website, click Start upload.
8. After the upload has finished, CIBANO 500 reboots automatically.
Note: Depending on the browser you are using you may wait up to 30 seconds for a response after
you pressed Start upload. Sometimes a message may appear that the server does not respond.
Ignore this message, after a while the upload will start automatically.
9. If you exited Primary Test Manager before upgrading the CIBANO 500 embedded software, start
Primary Test Manager again after the upgrade procedure has finished.
10.Connect to the CIBANO 500 device.