EasyManuals Logo

Omron SYSDRIVE 3G3RV Series User Manual

Omron SYSDRIVE 3G3RV Series
446 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #270 background imageLoading...
Page #270 background image
6
-
54
Multi-function
Digital
Inputs
(H1-01
to
H1-05)
nSetting
Precautions
• When
both
external
search
commands
1
and
2
are
set
for
the
multi-function
contact
terminals,
an
OPE03
(invalid
multi-function
input
selection)
operation
error
may
occur.
Set
either
external
search
command
1
or
external
search
command
2.
• If
speed
search
during
startup
is
selected
when
using
V/f
control
with
PG,
the
Unit
will
start
from
the
fre-
quency
detected
by
PG.
• If
performing
speed
search
using
external
search
commands,
add
an
external
sequence
so
that
the
period
when
the
run
command
and
external
search
command
are
both
ON
is
at
the
very
least
the
Minimum
Base-
block
Time
(L2-03).
• If
the
Inverter
output
is
equipped
with
a
contact,
set
the
contact
operation
delay
time
in
the
Speed
Search
Wait
Time
(b3-05).
The
factory
setting
is
0.2
s.
When
not
using
the
contact,
you
can
reduce
the
search
time
by
making
the
setting
0.0
s.
After
waiting
for
the
speed
search
wait
time,
the
Inverter
starts
the
speed
search.
• Parameter
b3-02
is
a
current
detection
speed
search
(current
detection
level
for
search
completion).
When
the
current
falls
below
the
detection
level,
the
speed
search
is
viewed
as
completed,
and
the
motor
acceler-
ates
or
decelerates
to
the
set
frequency.
If
the
motor
cannot
restart,
lower
the
set
value.
• If
an
overcurrent
(OC)
is
detected
when
using
speed
search
after
recovery
following
a
power
loss,
lengthen
the
Minimum
Baseblock
Time
(L2-03).
nApplication
Precautions
for
Speed
Searches
Using
Estimated
Speed
• When
using
V/f
control
with
or
without
a
PG,
always
perform
stationary
autotuning
for
only
line-to-line
resistance
before
using
speed
searches
based
on
estimated
speeds.
• When
using
open
loop
vector
control,
always
perform
rotational
autotuning
before
using
speed
searches
based
on
estimated
speeds.
• If
the
cable
length
between
the
motor
and
Inverter
is
changed
after
autotuning
has
been
performed,
per-
form
stationary
autotuning
for
only
line-to-line
resistance
again.
Set
Value
Function
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
61
External
search
command
1
OFF:
Speed
search
disabled
(Start
from
lowest
output
frequency)
ON:
Speed
estimation
(Estimate
the
motor
speed,
and
start
search
from
estimated
speed)
Current
detection
(Start
speed
search
from
maximum
output
frequency)
Yes N o Ye s
62
External
search
command
2
OFF:
Speed
search
disabled
(Start
from
lowest
output
frequency)
ON:
Speed
estimation
(Estimate
the
motor
speed,
and
start
search
from
estimated
speed)
(Same
operation
as
exter-
nal
search
command
1)
Current
detection:
Start
speed
search
from
set
frequency
(reference
frequency
when
search
command
was
input).
Yes N o Ye s
IMPORTANT
The motor will not operate when stationary autotuning or stationary autotuning only for line-to-line
resistance is performed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals