A
djusting Frequency References
6
-
2
7
Adjusting
Frequency
References
This
section
explains
methods
of
adjusting
frequency
references.
K
KK
K Adjusting
Analog
Frequency
References
Gain
and
bias
are
among
the
parameters
used
to
adjust
analog
inputs.
nRelated
Parameters
*For
(-E)
models.
nAdjusting
Analog
Frequency
Reference
Using
Parameters
The
frequency
reference
is
input
from
the
control
circuit
terminals
using
analog
voltage
and
current.
If
using
frequency
reference
terminal
A1
as
an
input
terminal,
perform
adjustments
using
parameters
H3-02
and
H3-03.
If
using
multi-function
analog
input
terminal
A2
as
a
frequency
reference
terminal,
perform
adjustments
using
H3-10
and
H3-11.
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
LCD
Display
H3-01
Signal
select
terminal
A1
(voltage)
0:
Voltage
limit
enabled
(Below
0
V
is
0
V)
1:
Voltage
limit
disabled
Set
value
1
can
be
set
for
(-E)
models.
0
or
10 No
A
*
A
*
A
*
Term
A1
Lvl
Sel
H3-02
Gain
(terminal
A1)
Set
the
frequency
during
10
V
input
as
a
percent,
taking
max.
output
frequency
to
be
100%.
0.0
to
1000.0
100.0% Yes A A A
Term inal
A1
Gain
H3-03
Bias
(terminal
A1)
Set
the
frequency
during
0
V
input
as
a
percent,
taking
max.
output
frequency
to
be
100%.
-100.0
to
+100.0
0.0% Yes A A A
Term inal
A1
Bias
H3-08
Multi-function
analog
input
terminal
A2
signal
level
selection
0:
Limit
negative
frequency
settings
for
gain
and
bias
settings
to
0.
1: Do
not
limit
negative
frequency
settings
for
gain
and
bias
settings
to
0
(i.e.,
allow
reverse
operation).
2:
4
to
20
mA
(9-bit
input).
Switch
current
and
voltage
input
using
the
switch
on
the
control
panel.
0
to
22 NoAAA
Term
A2
Signal
H3-09
Multi-function
analog
input
terminal
A2
function
selection
Select
multi-function
analog
input
function
for
ter-
minal
A2.
0
to
1F 0 No A A A
Term inal
A2
Sel
H3-10
Gain
(terminal
A2)
Set
the
reference
capacity
for
each
function
during
10
V
(20 mA)
input
as
a
percent.
Set
the
100%
content
function
selected
using
H3-
09
to
100%.
0.0
to
1000.0
100.0% Yes A A A
Term inal
A2
Gain
H3-11
Bias
(terminal
A2)
Set
the
reference
capacity
for
each
function
during
0
V
(4
mA)
input
as
a
percent.
Set
the
100%
content
function
selected
using
H3-
09
to
100%.
-100.0
to
+100.0
0.0% Yes A A A
Term inal
A2
Bias

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals