Page #353 background image
D
igital Operator Functions
6
-
1
37
nInitializing
Changed
Parameter
Values
You
can
save
to
the
Inverter
parameter
set
values
that
you
have
changed
as
parameter
initial
values.
Change
the
set
values
from
the
Inverter
factory
settings,
and
then
set
o2-03
to
1.
Set
A1-03
(Initialize)
to
1110
to
initialize
the
Inverter
parameters
using
the
user-set
initial
values
in
memory.
To
clear
the
user-set
initial
values
in
memory,
set
o2-03
to
2.
nSetting
the
Frequency
Reference
using
the
UP
and
DOWN
Keys
without
Using
the
Enter
Key
Use
this
function
when
inputting
frequency
references
from
the
Digital
Operator.
When
o2-05
is
set
to
1,
you
can
increment
and
decrement
the
frequency
reference
using
the
UP
and
DOWN
Keys
without
using
the
Enter
Key.
For
example,
enter
the
Run
command
using
a
0
Hz
reference,
and
then
continuously
press
the
UP
Key
to
increment
the
frequency
reference
by
0.01
Hz
only
for
the
first
0.5
s,
and
then
by
0.01
Hz
every
80
ms
for
3
s
thereafter.
Press
and
hold
down
the
UP
Key
for
3
s
minimum
to
reach
the
maximum
output
frequency
10
s
after
that.
The
frequency
reference
that
has
been
set
will
be
stored
in
memory
5
s
after
the
UP
or
DOWN
Keys
are
released.
nClearing
Cumulative
Operation
Time
Set
the
cumulative
operation
time
initial
value
in
time
units
in
parameter
o2-07.
Set
o2-07
to
0
to
clear
U1-13
(Inverter
Operating
Time).
nClearing
Inverter
Cooling
Fan
Operation
Time
Set
the
fan
operation
time
initial
value
in
time
units
in
parameter
o2-10.
Set
o2-10
to
0
to
clear
U1-40
(Cooling
Fan
Operating
Time).
K
KK
K Copying
Parameters
The
Digital
Operator
can
perform
the
following
three
functions
using
the
built-in
EEPROM
(non-volatile
memory).
• Store
Inverter
parameter
set
values
in
the
Digital
Operator
(READ)
• Write
parameter
set
values
stored
in
the
Digital
Operator
to
the
Inverter
(COPY)
• Compare
parameter
set
values
stored
in
the
Digital
Operator
with
Inverter
parameters
(VERIFY)
nRelated
Parameters
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
LCD
Display
o3-01
Copy
function
selection 0:
Normal
operation
1:
READ
(Inverter
to
Operator)
2:
COPY
(Operator
to
Inverter)
3:
Verif y
(compare)
0
to
30 NoAAA
Copy
Func
Select
o3-02
Read
permitted
selection
0:
Read
prohibited
1:
Read
permitted
0
or
10 NoAAA
Copy
Allowable

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals