C
onnection
Diagrams
2
-
5
K
KK
K European
Models
The
connection
diagram
for
the
European
models
is
shown
in
Fig.
2.3.
Fig
2.3
Connection
Diagram
for
European
(-E)
Models
Inverter
3G3RV
U/T1
V/T2
W/T3
(Ground to 100
W
max.)
MA
MB
MC
Error contact output
250 VAC, 1 A max.
30 VDC, 1 A max.
M1
M2
Multi-function contact output
250 VAC, 1 A max.
30 VDC, 1 A max.
Default: Running
signal
M3
M4
Multi-function output 1
250 VAC, 1 A max.
30 VDC, 1 A max.
(Default: Zero-speed)
M5
M6
Multi-function output 2
250 VAC, 1 A max.
30 VDC, 1 A max.
(Default: Frequency agree 1)
P
4to20mA
0to10V
Pulse train input
RP
+V
-V
A1
A2
AC
0V
Master speed pulse train
0 to 32 kHz (3 k
W
)
High level: 3.5 to 13.2 V input
Frequency setting power
+15 V, 20 mA
Frequency setting power
-15 V, 20 mA
Master speed reference
0to10V(20k
W
)
Master speed reference
4 to 20 mA (250
W
)
[0 to 10 V (20 k
W
) input]
Frequency setting
adjustment
Frequency
setter
External
frequency
references
IG
RS-422A/485
communications
R-
R+
S-
S+
Terminating
resistance
A
C
MP
Pulse train output
0 to 32 kHz (2.2 k
W
)
Default: Output
frequency
3-phase power
200 to 240 V
50/60 Hz
T/L3
S/L2
R/L1
MCCB
T
S
R
S5
S6
S7
SN
SP
SC
E(G)
Multi-step speed
setting 1
M
u
l
t
i
-step spee
d
settin
g
2
Jog frequency selection
(PNP connection)
Shield terminal
S1
S2
S3
S4
Forward Run/Stop
Reverse Run/Stop
External fault
Fault reset
Multi-function
contact inputs
FM
AM
Multi-function analog output 1
AC
E
(
G
)
-
10 to 10 V 2 mA
FM
Default: Output frequency
0 to +10 V
Default: Output current
0 to +10 V
-10 to 10 V 2 mA
Multi-function analog output 2
A
mmeter adjustment
B2B1
Short-circuit bar
UX
Ammeter adjustment
+24 V 8 mA
DC reactor to improve
input power factor (optional)
Braking Resistor Unit (optional)
IM
Shield Twisted-pair wires
P
Factory
settings
+1
+2
CN15
V/I Converter
0to10V
/4 to 20 mA
CN15
V/I Converter
0to10V
/4 to 20 mA
24 V
+
-

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals