nput Terminal Functions
6
-
6
5
nApplication
Precautions
• When
d4-01
is
set
to
1,
the
output
frequency
on
hold
is
stored
even
after
the
power
supply
is
turned
OFF.
If
performing
operations
using
this
frequency
after
the
Inverter
has
also
been
turned
OFF,
input
the
run
com-
mand
with
the
Acceleration/Deceleration
Ramp
Hold
turned
ON.
• When
d4-01
is
set
to
0
and
a
run
command
is
input
while
the
Acceleration/Deceleration
Ramp
Hold
is
turned
ON,
the
output
frequency
will
be
set
to
zero.
• If
you
input
an
Acceleration/Deceleration
Ramp
Hold
command
by
error
when
decelerating
during
posi-
tioning,
deceleration
may
be
canceled.
K
KK
K Raising
and
Lowering
Frequency
References
Using
Contact
Signals
(UP/
DOWN)
The
UP
and
DOWN
commands
raise
and
lower
Inverter
frequency
references
by
turning
ON
and
OFF
a
multi-
function
contact
input
terminal
S3
to
S7.
To
use
this
function,
set
one
of
the
parameters
H1-01
to
H1-05
(multi-function
input
terminal
S3
to
S7
func-
tion
selection)
to
10
(UP
command)
and
11
(DOWN
command).
Be
sure
to
allocate
two
terminals
so
that
the
UP
and
DOWN
commands
can
be
used
as
a
pair.
The
output
frequency
depends
on
the
acceleration
and
deceleration
time.
Be
sure
to
set
b1-02
(Run
command
selection)
to
1
(Control
circuit
terminal).
nRelated
Parameters
nPrecautions
When
setting
and
using
UP
and
DOWN
commands,
observe
the
following
precautions.
Setting
Precautions
If
multi-function
input
terminals
S3
to
S7
are
set
as
follows,
operation
error
OPE03
(Invalid
multi-function
input
selection)
will
occur:
• Only
either
the
UP
command
or
DOWN
command
has
been
set.
• UP/DOWN
commands
and
Acceleration/Deceleration
Ramp
Hold
have
been
allocated
at
the
same
time.
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
LCD
Display
d2-01
Frequency
reference
upper
limit
Set
the
output
frequency
upper
limit
as
a
percent,
taking
the
maximum
output
frequency
to
be
100%.
0.0
to
110.0
100.0% No A A A
Ref
Upper
Limit
d2-02
Frequency
reference
lower
limit
Set
the
output
frequency
lower
limit
as
a
percent-
age
of
the
maximum
output
frequency.
0.0
to
110.0
0.0% No A A A
Ref
Lower
Limit
d2-03
Master
speed
reference
lower
limit
Set
the
master
speed
frequency
reference
lower
limit
as
a
percent,
taking
the
maximum
output
fre-
quency
to
be
100%.
0.0
to
110.0
0.0% No A A A
Ref1
Lower
Limit

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals