roubleshooting
7
-
1
5
Troubleshooting
Due
to
parameter
setting
errors,
faulty
wiring,
and
so
on,
the
Inverter
and
motor
may
not
operate
as
expected
when
the
system
is
started
up.
If
that
should
occur,
use
this
section
as
a
reference
and
apply
the
appropriate
measures.
If
the
contents
of
the
fault
are
displayed,
refer
to
Protective
and
Diagnostic
Functions.
K
KK
K If
Parameters
Cannot
Be
Set
Use
the
following
information
if
an
Inverter
parameter
cannot
be
set.
nThe
display
does
not
change
when
the
and
Keys
are
pressed.
The
following
causes
are
possible.
The
Inverter
is
operating
(drive
mode).
There
are
some
parameters
that
cannot
be
set
during
operation.
Turn
the
Inverter
off
and
then
make
the
set-
tings.
Parameter
write
enable
is
turned
OFF.
This
occurs
when
“parameter
write
enable”
(set
value:
1B)
is
set
for
a
multi-function
input
terminal
(H1-01
to
H1-05).
If
the
parameter
write
enable
input
is
OFF,
the
parameters
cannot
be
changed.
Turn
it
ON
and
then
set
the
parameters.
Passwords
do
not
match.
(Only
when
a
password
is
set.)
If
the
parameter
A1-04
(Password)
and
A1-05
(Password
Setting)
numbers
are
different,
the
parameters
for
the
initialize
mode
cannot
be
changed.
Reset
the
password.
If
you
cannot
remember
the
password,
display
A1-05
(Password
Setting)
by
pressing
the
Reset
Key
and
the
Menu
Key
simultaneously
while
in
the
A1-04
display.
Then
reset
the
password.
(Input
the
reset
password
in
parameter
A1-04.)
nOPE01
through
OPE11
is
displayed.
The
set
value
for
the
parameter
is
wrong.
Refer
to
Operation
Errors
in
this
chapter
and
correct
the
setting.
nCPF00
or
CPF01
is
displayed./Nothing
appears
on
Digital
Operator
display.
This
is
a
Digital
Operator
communications
error.
The
connection
between
the
Digital
Operator
and
the
Inverter
may
be
faulty.
Remove
the
Digital
Operator
and
then
re-install
it.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals