EasyManuals Logo

Omron SYSDRIVE 3G3RV Series User Manual

Omron SYSDRIVE 3G3RV Series
446 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #345 background imageLoading...
Page #345 background image
I
ndividual Functions
6
-
1
29
K
KK
K Setting
the
V/f
Pattern
In
V/f
control
method,
you
can
set
the
Inverter
input
voltage
and
the
V/f
pattern
as
the
need
arises.
nRelated
Parameters
*1.These
are
values
for
a
200-V
Class
Inverter.
Val ue s
for
a
400-V
Class
Inverter
are
double.
*2.The
factory
setting
will
change
when
the
control
method
is
changed.
(V/f
control
factory
settings
are
given.)
*3.The
contents
of
parameters
E1-11
and
E1-12
are
ignored
when
set
to
0.00.
*4.E1-13
is
set
to
the
same
value
as
E1-05
by
autotuning.
*5.When
C6-01
is
set
to
0,
the
upper
limit
of
the
setting
range
is
150.0
Hz.
*6.For
(-E)
models.
Factory
setting
for
base
frequency
is
50
Hz.
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
LCD
Display
E1-01
Input
voltage
setting
Set
the
Inverter
input
voltage
in
1
volt.
This
setting
is
used
as
a
reference
value
in
protection
func-
tions.
155
to
255
*1
200
V
*1
No Q Q Q
Input
Voltage
E1-03
V/f
pattern
selection
0
to
E:
Select
from
the
15
preset
V/f
patterns.
F:
Custom
user-set
patterns
(Application
for
settings
E1-04
to
E1-10.)
0
to
F F No Q Q No
V/F
Selection
E1-04
Max.
output
frequency
(FMAX)
To
set
V/f
characteristics
in
a
straight
line,
set
the
same
values
for
E1-07
and
E1-09.
In
this
case,
the
setting
for
E1-08
will
be
disregarded.
Always
ensure
that
the
four
frequencies
are
set
in
the
following
manner:
E1-04
(FMAX) ≥
E1-06
(FA)
>E1-07
(FB)
≥
E1-09
(FMIN)
40.0
to
400.0
*5
60.0
Hz
(50.00
Hz)*6
No Q Q Q
Max
Frequency
E1-05
Max.
voltage
(VMAX)
0.0
to
255.0
*1
200.0
V
*1
*2
No Q Q Q
Max
Voltage
E1-06
Base
frequency
(FA)
0.0
to
400.0
60.0
Hz
(50.00
Hz)*6
No Q Q Q
Base
Frequency
E1-07
Mid.
output
frequency
0.0
to
400.0
3.0
Hz
*2
No A A A
Mid
Frequency
A
E1-08
Mid.
output
frequency
voltage
0.0
to
255.0
15.0
V
*1
*2
No A A A
Mid
Voltage
A
E1-09
Min.
output
frequency
(FMIN)
0.0
to
400.0
1.5
Hz
*2
No Q Q Q
Min
Frequency
E1-10
Min.
output
frequency
voltage
0.0
to
255.0
*1
9.0
V
*1
*2
No A A A
Min
Voltage
E1-11
Mid.
output
frequency
2
Set
only
to
fine-adjust
V/f
for
the
output
range.
Normally,
this
setting
is
not
required.
0.0
to
400.0
0.0
Hz
*3
No A A A
Mid
Frequency
B
E1-12
Mid.
output
frequency
voltage
2
0.0
to
255.0
*1
0.0
V
*3
No A A A
Mid
Voltage
B
E1-13
Base
voltage
0.0
to
255.0
*1
0.0
V
*4
No A A Q
Base
Voltage
Output voltage (V)
Frequency (Hz)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals