Omron SYSDRIVE 3G3RV Series User Manual

Omron SYSDRIVE 3G3RV Series
446 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #352 background imageLoading...
Page #352 background image
6
-
136
* Factory
settings
depend
on
Inverter
capacity.
(The
values
shown
are
for
a
200
V
Class
Inverter
for
0.4
kW.)
nChanging
Frequency
Reference
and
Display
Units
Set
the
Digital
Operator
frequency
reference
and
display
units
using
parameter
o1-03.
You
can
change
the
units
for
the
following
parameters
using
o1-03.
• U1-01
(Frequency
Reference)
• U1-02
(Output
Frequency)
• U1-05
(Motor
Speed)
• U1-20
(Output
Frequency
after
Soft
Start)
• d1-01
to
d1-17
(Frequency
references)
nSwitching
Monitors
when
the
Power
Supply
Is
ON
Using
parameter
o1-02,
select
the
monitor
item
(U1-oo
[status
monitor])
to
be
displayed
on
the
Digital
Operator
when
the
power
supply
is
turned
ON.
For
monitors
that
can
be
displayed,
refer
to
U1-oo
in
Chap-
ter
5
Parameters.
Setting
Precautions
If
selecting
monitor
parameters
other
than
U1-01
(Frequency
Reference),
U1-02
(Output
Frequency),
and
U1-
03
(Output
Current),
first
select
the
monitor
items
to
be
displayed
in
o1-01,
and
then
set
o1-02
to
4.
nDisabling
the
STOP
Key
If
b1-02
(Operation
Method
Selection)
is
set
to
1,
2,
or
3,
the
stop
command
from
the
STOP
Key
on
the
Digital
Operator
is
an
emergency
stop
command.
Set
o2-02
to
0
to
disable
emergency
stop
commands
from
the
STOP
Key
on
the
Digital
Operator.
nDisabling
the
LOCAL/REMOTE
Key
Set
o2-01
to
0
to
disable
the
LOCAL/REMOTE
Key
on
the
Digital
Operator.
You
cannot
switch
Inverter
ref-
erence
inputs
set
using
reference
inputs
from
the
Digital
Operator,
b1-01
(Reference
Selection),
or
b1-02
(Operation
Method
Selection).
o2-05
Frequency
reference
set-
ting
method
selection
Sets
the
operation
when
the
Digital
Operator
is
disconnected.
0:
Enter
key
needed
1:
Enter
key
not
needed
Inverter
output
is
cut
off,
and
fault
contact
is
operated.)
0
or
10 NoAAA
Operator
M.O.P.
o2-07
Cumulative
operation
time
setting
Sets
the
cumulative
operation
time
in
hour
units.
Operation
time
is
calculated
from
the
set
values.
0
to
65535
0NoAAA
Elapsed
Time
Set
o2-10
Fan
operation
time
setting Set
the
initial
value
of
the
fan
operation
time
using
time
units.
The
operation
time
accumulates
from
the
set
value.
0
to
65535
0NoAAA
Fan
ON
Time
Set
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
LCD
Display

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals