C
ontinuing Operation
6
-
5
9
nAuto
Restart
External
Outputs
To
output
auto
restart
signals
externally,
set
H2-01
to
H2-03
(multi-function
output
terminals
M1-M2,
M3-
M4,
M5-M6,
P1-PC,
and
P2-PC
function
selection)
to
1E
(auto
restart).
nRelated
Parameters
n
Application
Precautions
• The
number
of
auto
restarts
count
is
reset
under
the
following
conditions:
After
auto
restart,
normal
operation
has
continued
for
10
minutes.
After
the
protection
operation
has
been
performed,
and
the
error
has
been
verified,
and
an
error
reset
has
been
input.
After
the
power
supply
is
turned
OFF,
and
then
ON
again.
• Do
not
use
the
auto
restart
function
with
variable
loads.
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
LCD
Display
L5-01
Number
of
auto
restart
attempts
Set
the
number
of
auto
restarts
attempts.
Automatically
restarts
after
a
fault
and
conducts
a
speed
search
from
the
run
frequency.
0
to
10 0 No A A A
Num
of
Restarts
L5-02
Auto
restart
operation
selection
Sets
whether
a
fault
contact
output
is
activated
during
fault
restart.
0:
Not
output
(Fault
contact
is
not
activated.)
1:
Output
(Fault
contact
is
activated.)
0
or
10 NoAAA
Restart
Sel

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals