6
-
126
nAdjusting
Energy-saving
Control
The
method
of
adjustment
during
energy-saving
control
operations
differs
depending
on
the
control
method.
Refer
to
the
following
when
making
adjustments.
V/f
Control
In
V/f
control
method,
the
voltage
for
optimum
motor
efficiency
is
calculated
and
becomes
the
output
voltage
reference.
• b8-04
(Energy-saving
Coefficient)
is
set
at
the
factory
for
motor
use
applied
to
the
Inverter.
If
the
motor
capacity
differs
from
the
motor
applied
to
the
Inverter,
set
the
motor
capacity
in
E2-11
(Motor
Rated
Out-
put).
Also,
adjust
the
output
voltage
in
steps
of
5
until
it
reaches
minimum.
The
larger
the
energy-saving
coefficient,
the
greater
the
output
voltage.
• To
improve
response
when
the
load
fluctuates,
reduce
the
power
detection
filter
time
parameter
b8-05.
If
b8-05
is
set
too
small,
however,
motor
rotations
when
the
load
is
light
may
become
unstable.
• Motor
efficiency
varies
due
to
temperature
fluctuations
and
differences
in
motor
characteristics.
Conse-
quently,
control
motor
efficiency
online
to
optimize
efficiency
by
causing
minute
variations
in
voltage
using
the
search
operation.
Parameter
b8-06
(Search
Operation
Voltage
Limiter)
controls
the
range
that
control
the
voltage
using
the
search
operation.
For
200
V
Class
Inverters,
set
the
range
to
100%/200
V,
and
for
400
V
Class
Inverters,
set
the
range
to
100%/400
V.
Set
to
0
to
disable
the
search
operation.
Open
loop
vector
control
In
open
loop
vector
control,
control
the
slip
frequency
so
that
motor
efficiency
is
maximized.
• Taking
the
motor
rated
slip
for
the
base
frequency
as
optimum
slip,
calculate
the
optimum
slip
for
motor
efficiency
for
each
frequency.
In
vector
control,
be
sure
to
perform
autotuning,
and
set
the
motor
rated
slip.
• If
the
motor
performs
hunting
when
using
energy-saving
control
in
vector
control,
reduce
the
set
value
in
b8-02
(Energy-saving
Gain),
or
increase
the
set
value
in
b8-03
(Energy-saving
Filter
Time
Constant).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals