6
-
134
When
E1-03
is
set
to
F
(User-defined
V/f
pattern),
you
can
set
parameters
E1-04
to
E1-10.
If
E1-03
is
set
to
anything
other
than
F,
you
can
only
refer
to
parameters
E1-04
to
E1-10.
If
the
V/f
characteristics
are
linear,
set
E1-07
and
E1-09
to
the
same
value.
In
this
case,
E1-08
will
be
ignored.
Fig 6.79 User-Set V/f Pattern
nSetting
Precautions
When
the
setting
is
to
user-defined
V/f
pattern,
beware
of
the
following
points.
• When
changing
control
method,
parameters
E1-07
to
E1-10
will
change
to
the
factory
settings
for
that
control
method.
• Be
sure
to
set
the
four
frequencies
as
follows:
E1-04
(FMAX)
≥
E1-06
(FA)
>
E1-07
(FB)
≥
E1-09
(FMIN)
Output voltage (V)
E1-05
(VMAX)
E1-13
(V Base)
E1-08
(VC)
E1-10
(VMIN)
E1-09
(
FMIN
)
E1-07
(
FB
)
E1-06
(
FA
)
E1-04
(
FMAX
)
Frequency (Hz)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals