When
E1-03
is
set
to
F
(User-defined
V/f
pattern),
you
can
set
parameters
E1-04
to
E1-10.
If
E1-03
is
set
to
anything
other
than
F,
you
can
only
refer
to
parameters
E1-04
to
E1-10.
If
the
V/f
characteristics
are
linear,
set
E1-07
and
E1-09
to
the
same
value.
In
this
case,
E1-08
will
be
ignored.
Fig 6.79 User-Set V/f Pattern
nSetting
Precautions
When
the
setting
is
to
user-defined
V/f
pattern,
beware
of
the
following
points.
When
changing
control
method,
parameters
E1-07
to
E1-10
will
change
to
the
factory
settings
for
that
control
method.
Be
sure
to
set
the
four
frequencies
as
follows:
E1-04
(FMAX)
E1-06
(FA)
>
E1-07
(FB)
E1-09
(FMIN)
Output voltage (V)
E1-05
(VMAX)
E1-13
(V Base)
E1-08
(VC)
E1-10
(VMIN)
E1-09
(
FMIN
)
E1-07
(
FB
)
E1-06
(
FA
)
E1-04
(
FMAX
)
Frequency (Hz)