P
rotective and Diagnostic Functions
7
-
9
(blink-
ing)
Over-
torque
Det
1
Overtorque 1
There
has
been
a
current
greater
than
the
setting
in
L6-02
for
longer
than
the
setting
in
L6-03.
-
•Make
sure
that
the
settings
in
L6-02
and
L6-03
are
appropriate.
•Check
the
mechanical
system
and
correct
the
cause
of
the
overtorque.
(blink-
ing)
Over-
torque
Det
2
Overtorque 2
There
has
been
a
current
greater
than
the
setting
in
L6-05
for
longer
than
the
setting
in
L6-06.
-
•Make
sure
that
the
current
setting
in
L6-05
and
time
setting
in
L6-06
are
appropriate.
•Check
the
mechanical
system
and
correct
the
cause
of
the
overtorque.
(blink-
ing)
Under-
torq
Det
1
Undertorque 1
There
has
been
a
current
less
than
the
setting
in
L6-02
for
longer
than
the
setting
in
L6-03.
-
•Make
sure
that
the
settings
in
L6-02
and
L6-03
are
appropriate.
•Check
the
mechanical
system
and
correct
the
cause
of
the
overtorque.
(blink-
ing)
Under-
torq
Det
2
Undertorque 2
There
has
been
a
current
less
than
the
setting
in
L6-05
for
longer
than
the
setting
in
L6-06.
-
•Make
sure
that
the
current
setting
in
L6-05
and
time
setting
in
L6-06
are
appropriate.
•Check
the
mechanical
system
and
correct
the
cause
of
the
overtorque.
(blink-
ing)
Over-
speed
Det
Overspeed
The
speed
has
been
greater
than
the
setting
in
F1-08
for
longer
than
the
setting
in
F1-09.
Overshooting/undershooting
are
occurring.
Adjust
the
gain
again.
The
reference
speed
is
too
high.
Check
the
reference
circuit
and
refer-
ence
gain.
The
settings
in
F1-08
and
F1-09
aren't
appropriate.
Check
the
settings
in
F1-08
and
F1-09.
(blink-
ing)
PG
Open
The PG is disconnected
The
Inverter
is
outputting
a
frequency,
but
PG
pulses
aren't
being
input.
There
is
a
break
in
the
PG
wiring. Fix
the
broken/disconnected
wiring.
The
PG
is
wired
incorrectly. Fix
the
wiring.
Power
isn't
being
supplied
to
the
PG. Supply
power
to
the
PG
properly.
(blink-
ing)
Speed
Devia-
tion
Excessive Speed Deviation
The
speed
deviation
has
been
greater
than
the
setting
in
F1-10
for
longer
than
the
setting
in
F1-11.
The
load
is
too
large. Reduce
the
load.
The
acceleration
time
and
decelera-
tion
time
are
too
short.
Lengthen
the
acceleration
time
and
deceleration
time.
The
load
is
locked. Check
the
mechanical
system.
The
settings
in
F1-10
and
F1-11
aren't
appropriate.
Check
the
settings
in
F1-10
and
F1-11.
Opt
External
Flt
External error detected for Com-
munications Card other than SI-K2
Continuing
operation
was
specified
for
EF0
(F6-03
=
3)and
an
external
fault
was
input
from
the
Option
Card.
- Remove
the
cause
of
the
external
fault.
Table 7.2 Alarm Displays and Processing (Continued)
Display Meaning Probable causes Corrective Actions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals