M
aintenance and Inspection
8
-
3
Periodic
inspection
standards
vary
depending
on
the
Inverter's
installation
environment
and
usage
conditions.
The
Inverter's
maintenance
periods
are
noted
below.
Keep
them
as
reference.
Note The
standard
replacement
period
is
based
on
the
following
usage
conditions:
Ambient
temperature:Yearly
average
of
30°C
Load
factor:
80%
max.
Operating
rate:
12
hours
max.
per
day
Fig 8.2 Part Replacement Guidelines
Part Standard Replacement Period Replacement Method
Cooling
fan 2
to
3
years Replace
with
new
part.
Smoothing
capacitor 5
years
Replace
with
new
part.
(Determine
need
by
inspection.)
Breaker
relays - Determine
need
by
inspection.
Fuses 10
years Replace
with
new
part.
Aluminum
capacitors
on
PCBs 5
years
Replace
with
new
board.
(Determine
need
by
inspection.)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish

Related product manuals