EasyManuals Logo

Omron SYSDRIVE 3G3RV Series User Manual

Omron SYSDRIVE 3G3RV Series
446 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #397 background imageLoading...
Page #397 background image
S
tandard Inverter Specifications
9
-
3
n400-V
Class
Inverters
*For
applications
of
a
NEMA1
mounting,
remove
the
top
and
bottom
covers
and
treat
as
IP00.
Table 9.2 Specifications for 400-V Class Inverters
Model
3G3RV-
A4004 A4007 A4015 A4022 A4037 A4040 A4055 A4075 A4110 A4150 A4185
Max.
applicable
motor
output
(kW) 0.4 0.75 1.5 2.2 3.7 4 5.5 7.5 11 15 18.5
Output
specifi-
cations
Rated
output
capacity
(kVA)
1.41.62.84 5.86.69.513 18 24 30
Rated
output
current
(A) 1.8 2.1 3.7 5.3 7.6 8.7 12.5 17 24 31 39
Max.
output
voltage
(V) 3-phase,
380
to
480
VA C
(Depends
on
input
voltage.)
Max.
output
frequency
(Hz)
CT
(low
carrier,
fixed
torque
applications):
150
Hz
VT
(high
carrier,
variable
torque
applications):
400
Hz
Power
supply
specifications
Rated
voltage
(V)
Rated
frequency
(Hz)
3-phase,
380
to
480
VA C
50/60
Hz
Allowable
voltage
fluctua-
tion
-15%
to
+10%
Allowable
frequency
fluctu-
ation
±5%
Power
supply
capacity
(kVA)
1.7 1.9 3.3 4.9 6.9 7.9 12 15 22 28 36
Power
consumption
(W) 53 58 84 115 148 148 209 307 410 498 634
Approx.
weight
(kg) 3.03.03.04.04.04.04.06.06.010 10
Measures
for
power
supply
harmonics Optional
DC
reactor
Protective
structure
Enclose,
wall-mounting
(NEMA1:
Equivalent
to
IP20)
or
Mounted
in
a
panel
(equivalent
to
IP00)
*
Model
3G3RV-
B4220 B4300 B4370 B4450 B4550 B4750 B4900 B411K B413K B416K
Max.
applicable
motor
output
(kW) 22 30 37 45 55 75 90 110 132 160
Output
specifi-
cations
Rated
output
capacity
(kVA)
34 46 57 69 85 110 140 160 200 230
Rated
output
current
(A) 45 60 75 91 112 150 180 216 260 304
Max.
output
voltage
(V) 3-phase,
380
to
480
VA C
(Depends
on
input
voltage.)
Max.
output
frequency
(Hz)
CT
(low
carrier,
fixed
torque
applications):
150
Hz
VT
(high
carrier,
variable
torque
applications):
400
Hz
Power
supply
specifications
Rated
voltage
(V)
Rated
frequency
(Hz)
3-phase,
380
to
480
VA C
50/60
Hz
Allowable
voltage
fluctua-
tion
-15%
to
+10%
Allowable
frequency
fluc-
tuation
±5%
Power
supply
capacity
(kVA)
38 52 63 76 91 125 151 181 217 254
Power
consumption
(W) 725 995 1144 1316 1698 1974 2285 2950 3390 3938
Approx.
weight
(kg) 21 21 36 36 36 88 89 102 120 160
Measures
for
power
supply
harmonics Built-in
DC
reactor Built-in
DC
reactor
Protective
structure
Mounted
in
a
panel
(equivalent
to
IP00)
Mounted
in
a
panel
(equivalent
to
IP00)
*

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3RV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3RV Series Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3RV Series
CategoryInverter
LanguageEnglish