203
Before
execution
After
execution
4CIO 0002 5 6 7
0CIO 0030 0 1 0
0D00410 0 0 0
4567
0010
4567
CIO 0002
CIO 0030
D00410
5-15-15DATA COLLECT: COLL(045)
Variations
j COLL(045)
(045)
COLL SBs Of D
Operand Data AreasLadder Symbol
SBs: Source base CIO, G, A, T, C, DM
D: Destination word CIO, G, A, T, C, DM, DR, IR
Of: Offset data CIO, G, A, T, C, #, DM, DR, IR
When the execution condition is OFF, COLL(045) is not executed. When the ex-
ecution condition is ON, COLL(045) copies the content of SBs + Of to D, i.e., Of
is added to SBs to determine the source word.
2
D
3452
SBs + Of
345
Of must be BCD.
Note Refer to page 115 for general precautions on operand data areas.
Flags ER (A50003): Of is not BCD.
Content of *DM word is not BCD when set for BCD.
EQ (A50006): Content of S is 0.
N (A50008): Same status as bit 15 of D after execution.
Example When CIO 000005 is ON in the following example, the source word (CIO 0007) is
calculated by adding 5 (the content of CIO 0020) to the source base word
(CIO 0002). The content of CIO 0007 is then copied to the destination word
(D00200).
Address Instruction Operands
00000 LD 000005
00001 COLL(045)
0002
0020
D00200
Before
execution
After
execution
0CIO 0020 0 0 5
4CIO 007 0 9 5
0D00200 0 0 0
0005
4095
4095
CIO 0020
CIO 007
D00200
Description
Precautions
Data Movement Instructions Section 5-15
(045)
COLL 0002 0020 D00200