629
Revision History
A manual revision code appears as a suffix to the catalog number on the front cover of the manual.
Cat. No. W202-E1-5
Revision code
The following table outlines changes made to the manual. Page numbers refer to the previous version.
Revision code Date Revised content
1 June 1992 Original production
1A July 1992
Page 58: Descriptions for “Greater Than Flag, GR” and “Less Than Flag, LE” changed.
2 January 1993 PC setup defaults added to appendices and following corrections made.
Page 7 and 8: Personal Computer Unit added to table.
Page 8: Unclear entries removed from table and maximum number of words transferable
in SYSMAC NET System corrected to 990.
Page 17: Notes added to table.
Page 20: “EEPROM” removed from last paragraph.
Page 24: Note on restrictions on Peripheral Devices connected to Slaves added.
Page 42 and others: Maximum value for seconds corrected to 59.
Page 56: “Group-2” corrected to “Group–1,” “Group-3” corrected to “Group–2,” and
“(Group-3 Slaves)” added to fifth line of bottom table.
Page 58: “First” and “second” reversed for GR and LE.
Page 65: Last address in second line corrected to CIO 1897.
Page 71: First operand in table corrected to 000000.
Page 72: First instruction in second mnemonic table corrected to LD NOT.
Page 75: Vertical line between conditions removed.
Page 76: Mnemonic tables corrected for top ladder diagram.
Page 81 and others: Leading zeros added to make six-digit addresses for CIO Area.
Page 89: “, and certain unused bits in the AR area,” removed from second paragraph in
section 4-9.
Page 99/100: Missing text restored.
Page 102 and others: Leading zeros cut to make four-digit timer addresses.
Page 103 and 104: DM removed as a possible operand.
Page 109: Timing chart lines for jSET and iSET reversed.
Page 117: Temporary bits removed from program; MOVR added; mnemonics corrected.
Page 118, 119, 121, 122,: Precaution added; example programs modified accordingly.
Page 122: Second LD in second program changed to AND.
Page 125: LD added to mnemonics and precaution added.
Page 142 and 143: Description of ASFT(052) corrected and revised, including reversing
direction of data shift.
Page 145: Precaution added.
Page 155: Operands for OUT in top diagram corrected.
Page 159: “Upper limits” changed to “Compare table” in diagram.
Page 179: Second operand for second SUB(071) corrected.
Page 187: Positions of “=R” and other callouts lowered one line.
Page 187, 189, 210, 253, 271, 272: “025504” changed to A50004,” “025515” changed to
A50015,” and “025512” changed to A50012.”
Page 207: “02AE” changed to “E02A.”
Page 214: Second and next to last lines of bottom table corrected.
Page 217: Description for
Example
corrected.
Page 230, 232, and 234: Ladder diagrams corrected and note added (page 232).
Page 254: Direction of arrow reversed.
Page 263, 266, 268: Precaution added.
Page 264 and 266: Control data and node number corrected in
Example
.
Page 280: “D100000” corrected to “D10000” in first paragraph of
Example
.
Page 291: Program modified.
Page 298 and 300: Input and output refreshing actions modified.
Page 301: Timer refreshing actions modified.
Page 325: “(SYSMAC BUS/2)” added to L and M settings and “(SYSMAC BUS/2 and
SYSMAC BUS)” added to N setting.
Page 328: First “SYSMAC BUS” corrected to “SYSMAC BUS/2” in N setting.
Page 329 and 330: “IORF” corrected to “IOIF” in T setting.
Page 344: Following mnemonics corrected: 030: MOVE to MOV; 078: SLD to STC; and
079: SRD to CLC.
Page 357 and 358: DM removed as possible operand.

Table of Contents