Omron SYSMAC CV Series - Floating-Point Subtract: -F(455)

Omron SYSMAC CV Series
636 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
300
UF (A50010): Absolute value of the result is less than the minimum value
that can be expressed for floating-point data.
5-21-6 FLOATING-POINT SUBTRACT: –F(455)
(455)
–F Mi Su R
Ladder Symbol
Variations
–F(455)
Operand Data Areas
Mi: First minuend word CIO, G, A, T, C, #, DM
R: First result word CIO, G, A, DM
Su: First subtrahend word CIO, G, A, T, C, #, DM
When the execution condition OFF, –F(455) is not executed. When the execu-
tion condition is ON, –F(455) subtracts the 32-bit floating-point content of Su and
Su+1 from the 32-bit floating-point content of Mi and Mi+1 and places the result
in R and R+1.
R+1 R
Mi Minuend (floating-point data, 32 bits)
Mi+1
Su Subtrahend (floating-point data, 32 bits)
Su+1
Result (floating-point data, 32 bits)
If the absolute value of the result is greater than the maximum value that can be
expressed for floating-point data, the Overflow Flag (A50009) will turn ON and
the result will be output as ±.
If the absolute value of the result is less than the minimum value that can be ex-
pressed for floating-point data, the Underflow Flag (A50010) will turn ON and the
result will be output as 0.
The various combinations of minuend and subtrahend data will produce the re-
sults shown in the following table.
Minuend
Subtrahend 0 Numeral + NaN
0 0 Numeral +
Numeral Numeral
See
note
1.
+
+ ER
+ + + ER
NaN
ER
Note 1. The results could be zero (including underflows), a numeral, +, or –.
2. ER: The Error Flag (A50003) turns ON and the instruction is not executed.
Precautions Mi, Mi+1, Su, and Su+1 must be floating-point data.
Note Refer to page 115 for general precautions on operand data areas.
Flags ER (A50003): Mi, Mi+1, Su, and Su+1 are not floating-point data.
The content of a*DM word is not BCD when set for BCD.
EQ (A50006): The exponent and mantissa of the result are 0.
N (A50008): The result is a negative number.
OF (A50009): The absolute value of the result is greater than the maximum
value that can be expressed for floating-point data.
Description
(CVM1 V2)
Floating-point Math Instructions
Section 5-21