5-26-5 CLOCK COMPENSATION: DATE(179)
(179)
DATE C
Ladder Symbol
Variations
↑DATE(179)
Operand Data Areas
C: Control word CIO, G, A, T, C, DM
Description When the execution condition OFF, DATE(179) is not executed. When the ex-
ecution condition is ON, DATE(179) changes the internal clock setting according
to the clock data in four consecutive control words (first word: C). The internal
clock setting is copied to the clock function area (G001 to G004).
Word 15 to 08 07 to 00
C Minute (00 to 59) Second (00 to 59)
C+1 Day (01 to 31) Hour (00 to 23)
C+2 Year (00 to 99)* Month (01 to 12)
C+3 ––– Day (00 to 06)
00: Sunday
01: Monday
02: Tuesday
03: Wednesday
04: Thursday
05: Friday
06: Saturday
Note *Set the last two digits of the year.
Precautions The lower limit (C) must be less than or equal to the upper limit (C+1).
An error will not be generated even if the internal clock is set to a non-existent
date (such as November 31, for example).
Note Refer to page 115 for general precautions on operand data areas.
Flags ER (A50003): The control word is not within the allowable range.
The content of a*DM word is not BCD when set for BCD.
(CVM1 V2)
Time Instructions Section 5-26