EasyManua.ls Logo

Omron SYSMAC CV Series - Clock Compensation: Date(179)

Omron SYSMAC CV Series
636 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
353
90 04
12 18
40 30
1532
27 19
90 02
07 22
13 11
C + 2 : D00102
C + 1 : D00101
C : D00100
T + 1 : D02001
T : D02000
R + 2 : D00502
R + 1 : D00501
R : D00500
5-26-5 CLOCK COMPENSATION: DATE(179)
(179)
DATE C
Ladder Symbol
Variations
DATE(179)
Operand Data Areas
C: Control word CIO, G, A, T, C, DM
Description When the execution condition OFF, DATE(179) is not executed. When the ex-
ecution condition is ON, DATE(179) changes the internal clock setting according
to the clock data in four consecutive control words (first word: C). The internal
clock setting is copied to the clock function area (G001 to G004).
Word 15 to 08 07 to 00
C Minute (00 to 59) Second (00 to 59)
C+1 Day (01 to 31) Hour (00 to 23)
C+2 Year (00 to 99)* Month (01 to 12)
C+3 ––– Day (00 to 06)
00: Sunday
01: Monday
02: Tuesday
03: Wednesday
04: Thursday
05: Friday
06: Saturday
Note *Set the last two digits of the year.
Precautions The lower limit (C) must be less than or equal to the upper limit (C+1).
An error will not be generated even if the internal clock is set to a non-existent
date (such as November 31, for example).
Note Refer to page 115 for general precautions on operand data areas.
Flags ER (A50003): The control word is not within the allowable range.
The content of a*DM word is not BCD when set for BCD.
(CVM1 V2)
Time Instructions Section 5-26

Table of Contents

Related product manuals