449
Example In the following example, B will be executed after the execution of A and after
7,000 counts of CIO 000100 while CIO 000000 is ON.
CNTW<014>
A
B
BEND<001>
0005
#7000
000100
Address Instruction Operands
000000 LD 000000
000001 BPRG(250) 00
A
000200 CNTW<014> 0005
# 7000
000100
B
000300 BEND<001>
(250)
BPRG 00
0000
00
Flags ER (A50003): SV data is not BCD.
Indirectly addressed DM word is non-existent. (Content of
*DM word is not BCD, or the DM area boundary has been
exceeded.)
Block Programming Instructions Section 5-38