EasyManua.ls Logo

Oracle Exadata X10M - Drive Components

Oracle Exadata X10M
276 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table E-4 (Cont.) Disk Backplane Components
Component Name
(Oracle ILOM CLI
Targets)
IPMI Type Description Values (if applicable)
/SYS/DBP/HDD[0- x ]/
NVME/PRSNT
Discrete
sensor
NVMe device presence 01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/VREG_DBP_ERR
Discrete
sensor
Disk backplane voltage regulator-down
(VRD) error (Hidden)
01h-DEASSERTED
02h-ASSERTED
/SYS/VREG_USB_ERR
Discrete
sensor
Universal Serial Bus (USB) VRD error
(Hidden)
01h-DEASSERTED
02h-ASSERTED
Drive Components
The following table lists the hard disk drive (HDD) and solid state drive (SSD) components.
Table E-5 Drive Components
Component Name
(Oracle ILOM CLI
Targets)
IPMI Type Description Values (if applicable)
/SYS/DBP/HDD[0- x ]
FRU Hard disk drive FRU From host
/SYS/DBP/HDD[0- x ]/
PRSNT
Discrete
sensor
Hard disk drive presence 01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/DBP/HDD[0- x ]/
STATE
Discrete
sensor
Writable multistate, slot/connector sensor
type, per IPMI
01h-FAULT_STATUS
02h-IDENTITY
04h-INSTALLED
20h-SLOT_POWER_OFF
/SYS/DBP/HDD[0- x ]/
SERVICE
Indicator Hard disk drive Fault-Service Required
LED
Color: Amber
Location: HDD
Off: Normal
On: Hard disk drive was
diagnosed as faulty.
/SYS/DBP/HDD[0- x ]/
OK2RM
Indicator Hard disk drive OK to Remove LED Color: Blue
Location: HDD
Off: Normal
On: Drive is ready to remove.
/SYS/DBP/HDD[0- 3 ]/
NVME
FRU NVMe drive FRU
/SYS/DBP/HDD[0- 3 ]/
NVME/PRSNT
Discrete
sensor
NVMe device presence 01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/MB/SSDR[0-1]
FRU Internal M.2 SSD riser (2) FRU
/SYS/MB/SSDR[0-1]/
PRSNT
Discrete
sensor
Solid-state drive (SSD) riser presence (2
risers)
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
Appendix E
Drive Components
E-5

Table of Contents

Related product manuals