Table E-4 (Cont.) Disk Backplane Components
Component Name
(Oracle ILOM CLI
Targets)
IPMI Type Description Values (if applicable)
/SYS/DBP/HDD[0- x ]/
NVME/PRSNT
Discrete
sensor
NVMe device presence 01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/VREG_DBP_ERR
Discrete
sensor
Disk backplane voltage regulator-down
(VRD) error (Hidden)
01h-DEASSERTED
02h-ASSERTED
/SYS/VREG_USB_ERR
Discrete
sensor
Universal Serial Bus (USB) VRD error
(Hidden)
01h-DEASSERTED
02h-ASSERTED
Drive Components
The following table lists the hard disk drive (HDD) and solid state drive (SSD) components.
Table E-5 Drive Components
Component Name
(Oracle ILOM CLI
Targets)
IPMI Type Description Values (if applicable)
/SYS/DBP/HDD[0- x ]
FRU Hard disk drive FRU From host
/SYS/DBP/HDD[0- x ]/
PRSNT
Discrete
sensor
Hard disk drive presence 01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/DBP/HDD[0- x ]/
STATE
Discrete
sensor
Writable multistate, slot/connector sensor
type, per IPMI
01h-FAULT_STATUS
02h-IDENTITY
04h-INSTALLED
20h-SLOT_POWER_OFF
/SYS/DBP/HDD[0- x ]/
SERVICE
Indicator Hard disk drive Fault-Service Required
LED
Color: Amber
Location: HDD
Off: Normal
On: Hard disk drive was
diagnosed as faulty.
/SYS/DBP/HDD[0- x ]/
OK2RM
Indicator Hard disk drive OK to Remove LED Color: Blue
Location: HDD
Off: Normal
On: Drive is ready to remove.
/SYS/DBP/HDD[0- 3 ]/
NVME
FRU NVMe drive FRU
/SYS/DBP/HDD[0- 3 ]/
NVME/PRSNT
Discrete
sensor
NVMe device presence 01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/MB/SSDR[0-1]
FRU Internal M.2 SSD riser (2) FRU
/SYS/MB/SSDR[0-1]/
PRSNT
Discrete
sensor
Solid-state drive (SSD) riser presence (2
risers)
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
Appendix E
Drive Components
E-5