(Note 1)
The control 0 signal and control 1 signal cannot be assigned to the capture function if they are
assigned to the enable operation.
Setting item Settings Default value
Comparison match leading
edge reset / Comparison match
trailing edge reset
Selects a comparison match flag that resets the count
value at the rising edge or falling edge.
Not reset / Reset
Not reset
Comparison function (Settable for each counter)
Setting item Settings Default value
Select comparison function
Not use / Band comparison / Target value match
comparison
Not use
Select comparison input Count value Count value
Set number of comparison data
Sets the number of data items to be compared
Setting range: 1 to 16
16
If you select "Band comparison" or "Target value match comparison" for "Select comparison
function", set parameters for each comparison data item.
Setting item Settings Default value
Comparison data 0 to
Comparison data 15 (for band
comparison)
Specifies the lower and upper limits for each
comparison data
(Note 1)
Setting range: -2,147,483,648 to 2,147,483,647
0
Specifies the state of the comparison match flag when
the current value falls within the specified band
ON / OFF
OFF
Comparison data 0 to
Comparison data 15 (for target
value match comparison)
Specifies target values for each comparison data
Setting range: -2,147,483,648 to 2,147,483,647
0
Comparison match flags to be set or reset can be
selected for each status (incrementation or
decrementation) of comparison data that has reached
the target value.
Addition set pattern: Set / No change
Addition reset pattern: Reset / No change
Subtraction set pattern: Set / No change
Subtraction reset pattern: Reset / No change
No change
(Note 1)
Lower and upper limits can be set within the range between the lower and upper limits for the counter.
For linear counters, set each limit so that the lower limit is less than the upper limit. For ring counters,
lower and upper limits can be set in any range.
External output function (Settable for each counter)
Setting item Settings Default value
External output 0 signal setting Not output / Output Not output
External output 0 signal ON
hold time
Setting range: 0 to 1,000 (ms) 0 ms
External output 1 signal setting Not output / Output Not output
12.6 High-speed Counter Function
12-24 WUME-GM1RTXOP-01