● Enable count operation is used by allocating the enable function to the control flag. Count
operation is performed while the control flag is enabled.
●
Enable count operation can be set using the methods shown in the following table.
Types of control flag (enable processing)
Signal Setting method using the Counter_Configuration parameters
Enable condition
Count enable
request bit
- (No need to set) ●
Control 0 signal
Setting the enable operation conditions by setting up the control 0
signal function
● ●
Control 1 signal
Setting the enable operation conditions by setting up the control 1
signal function
● ●
(Note 1)
If you set the control 0 signal or control 1 signal as the enable operation condition, do not use the
count enable request bit.
Count enable operation example
■
Reset count operation
●
Reset count operation is used by allocating the reset function to the control flag.
● The count value is reset to 0 according to the change (rising, falling, positive logic, or
negative logic) of the control flag.
● Reset count operation can be set using the methods shown in the following table.
Types of control flag (reset processing)
Signal
Setting method using the
Counter_Configuration parameters
Reset condition
Reset request
bit
- (No need to set) ●
12.6 High-speed Counter Function
WUME-GM1RTXOP-01 12-35