2. Click Counter parameter>Counter (Ch0 or Ch1)>Comparison function>Comparison
data and specify target values for each comparison data item.
3.
Select "Addition set pattern", "Addition reset pattern", "Subtraction set pattern", and
"Subtraction reset pattern" separately and set ""No change", "Set output", or "Reset output""
for each comparison match flag.
4. Configure these settings for each comparison data item.
Settings can be configured individually according to the count direction (incremental or
decremental direction) at the time of comparison data match.
A total of 16 comparison match flags can be set separately for "Addition set pattern", "Addition
reset pattern", "Subtraction set pattern", and "Subtraction reset pattern".
For details on how to set up parameters, refer to "12.6.2 Setting Parameters with GM
Programmer".
Setting example for target value match function
Output setting example
Compariso
n data
Target
value
Output setting
Compariso
n match 0
flag
Compariso
n match 1
flag
Compariso
n match 2
flag
Compariso
n match 3
flag
0 +500
Addition set pattern
Addition reset pattern
Subtraction set pattern
Subtraction reset pattern
1 +1,250
Addition set pattern
Addition reset pattern
Subtraction set pattern
Subtraction reset pattern
2 +2,500
Addition set pattern
12.6 High-speed Counter Function
WUME-GM1RTXOP-01 12-43