When "rising edge" and "falling edge" of the same signal are specified as the
capture trigger conditions
The sign of the capture differential value changes according to the sequence of the capture
enable request bit and capture flag.
For continuous operation, capture 0 value, capture 1 value, and capture differential value are
overwritten each time a capture operation is completed.
Sampling capture function (one operation)
When the specified sampling time elapses after the capture flag turns ON or OFF, the count
value is stored in the capture 0 value and capture 1 value registers and the differential value
is stored in the capture differential value register.
The sampling capture function is always executable when the control 0 signal is allocated to
the sampling capture function.
The trigger condition that starts sampling capture can be selected from control 0 signal
(positive logic), control 1 signal (negative logic), and capture enable request bit (positive
logic).
For one operation, the capture 1 status bit is activated. Note that the capture 0 status bit is
not activated.
12.6 High-speed Counter Function