Timing chart
Sampling capture function (continuous operation)
Each time the specified sampling time elapses after the capture flag turns ON or OFF,
successively, the count value is stored in the capture 0 value and capture 1 value registers
and the differential value is stored in the capture differential value register.
The sampling capture function is always executable when the control 0 signal is allocated to
the sampling capture function.
The trigger condition that starts sampling capture can be selected from control 0 signal
(positive logic), control 0 signal (negative logic), and capture enable request bit (positive
logic).
For continuous operation, the capture 0 status bit is activated. Note that the capture 1 status
bit is not activated.
12.6 High-speed Counter Function
WUME-GM1RTXOP-01 12-55