PT Display—PT Last Display Duration in Idle Mode
Specifies the length of time that the current information remains on the display after the extension returns to
idle status.
Default
5
Value Range
1–15 s
Maintenance Console Location
10.3 PBX Configuration
—[2-3] System—Timers & Counters
Air Synchronization—Watching Degeneracy (x60s)
Specifies the length of time that a Slave CS can maintain an ongoing call after air synchronization is lost.
Default
300
Value Range
60 ´ n (n=0–300) s
Maintenance Console Location
10.3 PBX Configuration
—[2-3] System—Timers & Counters
Programming Manual References
19.2.1 PBX Configuration—[11-2-1] Maintenance—CS Synchronization—Air Synchronization
Voice Mail (Caller from VM to CO)—On-hook Wait Time
Specifies
the length of time from when the voice mail seizes a CO line (for example, to transfer a call) until the
voice mail goes on hook. If the time specified here is too short, the voice mail will be unable to dial the number
and make a connection.
Default
10
Value Range
1–30 s
Maintenance Console Location
10.3 PBX Configuration—[2-3] System—Timers & Counters
Feature Manual References
20.1.2 UNIFIED MESSAGING FEATURES