3.14 Overtemp (acts)
This occurs when the control system detects that the ISM’s actuator circuitry has
become too hot. The control system will cease drive to the actuator motor in
question.
Allow the ISM to cool.
If the ISM is frequently overheating check the condition of the
actuator motors and the connections to them.
If the trip persists contact your service agent.
3.15 Overtemp (lamps)
This occurs when the control system detects that ISM’s lighting circuitry has
become too hot. The control system will cease supplying current to the lamp in
question.
Allow the ISM to cool.
If the ISM is frequently overheating check the condition of all the
connected bulbs and lamps.
If the trip persists contact your service agent.
3.16 DIME Error
This occurs when the control system detects an identification conflict between
two modules in the system.
If a new module has been introduced:
Disconnect the new module and cycle the power.
If no trip is present connect the new module to the system and
cycle the power.
If the trip reappears then the new module must be the cause of
the problem.
If there has been no additions:
Disconnect one module at a time and cycle the power.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PG Drives Technology R-NET OMNI and is the answer not in the manual?

PG Drives Technology R-NET OMNI Specifications

General IconGeneral
BrandPG Drives Technology
ModelR-NET OMNI
CategoryWheelchair
LanguageEnglish

Related product manuals