v
measurements
setting up 31
switching on and off 25
mechanical damage 30
merging patient data 92
methemoglobin (SpO2) 155
microstream CO2
accessories
189
maintenance, calibration 278
measuring 189
mismatch
patient data, resolving 90
modified 12-lead ECG 109
modified screen history 20
modifying
screens
20
monitor
inspecting before use
30
starting monitoring 31
switching on 31
monitor (ECG filter setting) 104
monitor controls 12
monitor defaults 327
monitor revision
how to find 30
monitor settings 22
changing 29
monitoring
preparation 30
starting 30
monitoring mode 19
mounting information 3
MP20 11
MP20 Junior 11
MP30 11
multi-lead ST alarming 132
N
narrow alarm limits 49
navigating 13
permanent keys 15
SmartKeys 15
NBP
adult cuffs
286
alarm source 166
ANSI/AAMI SP10-1992 161
automatic mode, enabling 165
calibrating 167
calibration interval 278
comfort cuff kits 285
comfort cuffs 285
cuff pressure 164
cuff, applying 163
cuff, selecting 163
cuff, tightness 163
disposable cuffs 285
how the measurement works 161
measurement correction 163
measurement limitations 162
measurement methods, auto 162
measurement methods, manual 162
measurement methods, sequence 162
measurement methods, stat 162
measurement, starting 164
measurement, stopping 164
neonatal cuffs (disposable) 286
numerics 163
oscillometric method 161
pediatric cuffs 286
preparing to measure 162
repeat time 163
repeat time for automatic 165
repetition time, setting 165
reusable cuffs 285
single-hose disposable cuffs 286
site inspection 163
time of last measurement 163
units 163
venous puncture 167
neonates
Resp electrode placement 148
NER setup 223
network connection indicator 13
networked monitoring 32
new features 35
non-invasive blood pressure. See NBP
non-paced patients
arrhythmia monitoring
116
numerics
explanation of NBP display 163
nurse call 45
nurse call relay connection symbol 297
O
on screen calculator 18
operating 13
permanent keys 15
SmartKeys, using 15
operating mode 19
operating modes 19
configuration 19
demonstration 19
monitoring 19
passcode protection 19
service 19
operating room ECG cable 114
orange ECG cable 114
organizers 283, 284
oscillometric NBP measurement
method
161
other bed window 95
output
ECG
306
overlap
in recordings
240
overlapping screen trends 216
oxyCRG 219
OxyCRG event episodes 221
P
pace pulse rejection (ECG)
about 100
switching on/off 102
paced patients
arrhythmia monitoring
116
repolarization tails 102
safety information 114
setting status 114
paced status
checking
100
pacemaker failure 114
paper
loading 4
paper size
for reports 248
parameter scales
trends 212
passcode protection 19
patient
admit 85
category, NBP 161
discharge 88
end case 88
patient alarm messages 55
patient demographics window 85
patient mismatch 90
patient reports
contents 252
patient trends
viewing
207
paused alarms 44
extending time 45
restarting 45
performance specifications
pressure
309, 316
performance test 321
perfusion indicator 153, 154, 158
permanent 15
Philips contact information 296
physiological alarms 39
pleth alarm source 158
pleth wave 157