Chapter 1 Specifications
HF Series X-ray Generators - Service Manual Revision W
Quantum Medical Imaging 1-19
SYSTEM OPTIONS
The following lists the available options for HF Series X-Ray Generators. Note that
some options, such as QG-150 and Q-HSS, may only be used on certain generator
models (refer to Tables 1-5 through 1-7 for compatibility):
R80-HS: Exposure Hand Switch and R80-FS Foot Switch
QG-PDL: Operator Control Panel Pedestal Mount (used with ODYSSEY
control panel)
QG-WM: Operator Control Panel Wall Mount (used with ODYSSEY control
panel)
QGV-WM: Operator Control Panel Wall Mount (used with Q-VISION control
panel)
QG-150: 150 kV High Voltage Transformer (standard equipment on Models
QG-65 and QG-80)
Q-HSS: Internal High (Dual) Speed Starter Unit (standard equipment on
Models QG-65 and QG-80
Q-Connect: Enables ethernet connection to a PC computer using Quantum’s
"QBus" network integration software; required on systems utilizing a touch-
screen operator control panel
QG-28VPS: Internally mounted Auxiliary +28 VDC/8A Power Supply (only
available with three-phase input generators)
QG-TOMO: Provides interface for operation with Siemens and Pausch
tomographic systems (not available with Q-VISION HF Series OCP’s)
TechVision: Supplementary x-ray control panel, mounts on tube support
device. Refer to the TechVision Remote Control Panel Service and
Operator’s Manuals for complete installation and operation instructions.
NOTE: The use of ACCESSORY equipment not complying with the
equivalent safety requirements of this equipment may lead to
a reduced level of safety of the resulting system. Consider-
ation relating to the choice shall include:
-use of the accessory in the PATIENT VICINITY
-evidence that the safety certification of the ACCESSORY has
been performed in accordance with the appropriate IEC 601-1
and/or IEC 601-1-1 harmonized national standard.
SYSTEM OPERATING ENVIRONMENT
Ambient Temperature: +10°C to +40°C
Relative Humidity: 30 to 75%, non-condensing
Atmospheric Pressure: 700 hPa to 1060 hPa
Typical Heat Output of
Generator Cabinet: 3600 BTU per hour
Typical Heat Output of
operator control panel (OCP): 130 BTU per hour

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum ODYSSEY HF Series and is the answer not in the manual?

Quantum ODYSSEY HF Series Specifications

General IconGeneral
BrandQuantum
ModelODYSSEY HF Series
CategoryMedical Equipment
LanguageEnglish

Related product manuals