109
Automatic cycle
Enables an already initiated process to be
performed in a cyclic manner
Global
Global settings of doisng process
Batching outputs
Enables setting the outputs for dosing (fine
dosing in case of two-step dosing process)
Bulk batching output
Enables setting outputs for bulk dosing in
case of two-step dosing process
Correction
Enables determining global value of
correction for all weighing platforms
Maximum correctional
value
Enables detemining maximal value of
correction, which can be automatically
determined for all weighing platforms
<
Global> settings are dedicated for the process of creating simple dosing
processes, e.g.: dosing a single ingredient on all weighing platforms.
28.4. Description of functions and setting dosing process
While creating dosing process, the user has access to the following
functions:
Icon
Short
cut
Function Description
[DH]
Dose manually
Function recalling manual weighment of
dosing process ingredient (manual dosing)
Mass
Mass of an ingredient to be dosed
Min
MIN threshold for dosing process ingredient
Max
MAX threshold for dosing process ingredient
Product
Dosing process ingredient uploaded from
Products database
Down-weighing
Enables switching on checkweiging mode
(weighing on minus)
[DA]
Automatic batching
Function enabling automatic weighment
(automatic dosing). The function enables
controlling outputs dedicated for dosing
process.