Page #130 background image
8-14 Electromagnetic Compatibility (EMC) Rexroth IndraDrive
DOK-INDRV*-SYSTEM*****-PR02-EN-P
Limit Value Classes for HCS03 Drive Controllers with
HMS, HMD and HNF01 Drive Controllers
Drive controller
type
Mains filter type Max.
allowed
number of
axes
Max. allowed
total length
of motor
cable
[ m ]
PWM
frequ.
[kHz]
Allowed leakage
capacitance to comply
with limit value class
[ nF ]
HMS01;
HMD01
A2.1 A2.2 A1 B1
HCS03.1E-W0070 HNF01.1A-F240-E0051 6
240
110
4
8
12
16
tbd tbd tbd tbd
HCS03.1E-W0070 HNF01.1A-M900-E0051 12
900
270
4
8
12
16
tbd tbd tbd tbd
HCS03.1E-W0100 HNF01.1A-F240-R0094 6
240
110
4
8
12
16
tbd tbd tbd tbd
HCS03.1E-W0100 HNF01.1A-M900-R0094 12
900
270
4
8
12
16
tbd tbd tbd tbd
HCS03.1E-W0150 HNF01.1A-F240-E0125 6
240
110
4
8
12
16
tbd tbd tbd tbd
HCS03.1E-W0150 HNF01.1A-M900-E0125 12
900
270
4
8
12
16
tbd tbd tbd tbd
HCS03.1E-W0210 HNF01.1A-F240-E0202 6
240
110
4
8
12
16
tbd tbd tbd tbd
HCS03.1E-W0210 HNF01.1A-M900-E0202 12
900
270
4
8
12
16
tbd tbd tbd tbd
tbd in preparation
Fig. 8-10: HCS03 with mains filter HNF01
Note: HNF01.1 mains filters are not suited for operation on mains
grounded via outer conductor.
Observe allowed mains connection voltage in the respective
Project Planning Manual (max. 3AC480V)!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REXROTH IndraDrive C and is the answer not in the manual?

REXROTH IndraDrive C Specifications

General IconGeneral
Protection ClassIP20
Voltage Range200 V to 480 V
Input Voltage200 to 480 VAC
Control ModesSpeed, Torque, Position
Communication InterfacesPROFIBUS, CANopen, Ethernet
Feedback SystemsResolver, incremental encoder, absolute encoder

Related product manuals