Rexroth IndraDrive Specifications for the Components of the Drive System 5-3
DOK-INDRV*-SYSTEM*****-PR02-EN-P
5.2 Transport and Storage
Transport of the Devices
Conditions
temperature -25 ... 70 °C
relative humidity 5 ... 95%;
climatic category 2K3
absolute humidity 1 ... 60 g/m
3
climatic category 2K3
moisture condensation not allowed
icing not allowed
shock test out of operation according
to EN 60068-2-27
half sine in 3 axes:10g / 11ms
Fig. 5-4: Conditions for transport
Storage of the Devices
Conditions
temperature -25 ... 55 °C
relative humidity 5 ... 95%;
climatic category 1K3
absolute humidity 1 ... 29 g/m
3
climatic category 1K3
moisture condensation not allowed
icing not allowed
Fig. 5-5: Conditions for storage
Extended Storage
Some devices contain electrolytic capacitors which may deteriorate during
storage.
Note: When storing these devices for a longer period of time,
operate them once a year for at least 1 hour with power ON:
• devices HCS and HMV with mains voltage U
LN
• devices HMS, HMD, HLC with DC bus voltage U
DC