EasyManuals Logo

REXROTH IndraDrive C User Manual

REXROTH IndraDrive C
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
Rexroth IndraDrive Specifications for the Components of the Drive System 5-5
DOK-INDRV*-SYSTEM*****-PR02-EN-P
All Rexroth controls and drives are developed and tested according to the
state-of-the-art technology.
As it is impossible to follow the continuing development of all materials
(e.g. lubricants in machine tools) which may interact with our controls and
drives, it cannot be completely ruled out that any reactions with the
materials used by Bosch Rexroth might occur.
For this reason, before using the respective material a compatibility test
has to be carried out for new lubricants, cleaning agents etc. and our
housings/our housing materials.
Capacity Utilization
Where installation conditions differ, the following performance data are
reduced in accordance with the diagrams (see "Fig. 5-7: Capacity
utilization at higher ambient temperature" and "Fig. 5-8: Capacity
utilization at higher installation altitude"):
drive controller:
allowed continuous DC bus power
continuous power of braking resistor
continuous current
motor:
power
continuous torque at standstill
S1 continuous torques
short-time service torque MKB
If differing ambient temperatures and higher installation altitudes occur
simultaneously, both capacity utilization factors must be multiplied. The
installation altitude must only be taken into account once, deviating
ambient temperatures must be taken into account separately for motor
and drive controller.
DK000073v01_en
0,7
1
40 45 50 55
5
Load factor
Ambient temperature in °C
Fig. 5-7: Capacity utilization at higher ambient temperature
Compatibility with Foreign
Matters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REXROTH IndraDrive C and is the answer not in the manual?

REXROTH IndraDrive C Specifications

General IconGeneral
Protection ClassIP20
Voltage Range200 V to 480 V
Input Voltage200 to 480 VAC
Control ModesSpeed, Torque, Position
Communication InterfacesPROFIBUS, CANopen, Ethernet
Feedback SystemsResolver, incremental encoder, absolute encoder

Related product manuals