6-12 Configuration of the Drive System Rexroth IndraDrive Rexroth IndraDrive
DOK-INDRV*-SYSTEM*****-PR02-EN-P
CAUTION
Damage to the drive controller!
Do not exceed allowed peak and continuous powers
in the DC bus.
Combinations at Common DC Bus that are Not Allowed
CAUTION
Property damage caused by combinations that
are not allowed!
Only operate allowed combinations.
Operating the following combinations at the common DC bus is not
allowed
HCS02 with HMV
HCS03 with HMV
HCS02 with HCS03
Note: Operating components not mentioned in this documentation at
the common DC bus with Rexroth IndraDrive components
requires Rexroth's explicit confirmation.