1.SC Codes
143
Error Name/Error Condition/Major Cause/Solution
Replace the IOB.
Replace the harness between TSB and IOB.
Set the connector between TSB and IOB again.
Error Name/Error Condition/Major Cause/Solution
CIS error 4: registration: white level adjustment error: front CIS
CIS error 4: registration: white level error: front CIS
When turning on the power, recovering from energy saving, and the door is
closed
SC689-01: CIS right white level adjustment error
When printing
SC689-05: CIS right white level error
Sheet-through exposure glass on the TIM-Mag unit is dirty.
Shading plate on the revolver is dirty.
Harness defective/shortened
CRB-R defective
IOB defective
CIS defective
1. Cycle the main power switch off/on.
2. Clean the shading plate on the revolver.
3. Clean the sheet-trough exposure glass on the TIM-Mag unit.
4. Reconnect the harness between CIS and CRB-R.
5. Reconnect the harness between CRB-R and IOB.
6. Replace the harness between CIS and CRB-R.
7. Replace the harness between CRB-R and IOB.
8. Replace the CRB-R.
9. Replace the CIS.
10. Replace the IOB.
Error Name/Error Condition/Major Cause/Solution
Communication between CRB-L and IOB error
-01: CRB-L start signal is monitored at power-ON.