1.SC Codes
143
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
Replace the TSB.
Replace the IOB.
Replace the harness between TSB and IOB.
Set the connector between TSB and IOB again.
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
SC689-
01
B
CIS error 4: registration: white level adjustment error: front CIS
SC689-
05
B
CIS error 4: registration: white level error: front CIS
When turning on the power, recovering from energy saving, and the door is
closed
SC689-01: CIS right white level adjustment error
When printing
SC689-05: CIS right white level error
Harness disconnected
Sheet-through exposure glass on the TIM-Mag unit is dirty.
Shading plate on the revolver is dirty.
Harness defective/shortened
CRB-R defective
IOB defective
CIS defective
1. Cycle the main power switch off/on.
2. Clean the shading plate on the revolver.
3. Clean the sheet-trough exposure glass on the TIM-Mag unit.
4. Reconnect the harness between CIS and CRB-R.
5. Reconnect the harness between CRB-R and IOB.
6. Replace the harness between CIS and CRB-R.
7. Replace the harness between CRB-R and IOB.
8. Replace the CRB-R.
9. Replace the CIS.
10. Replace the IOB.
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
SC690-01
D
CRB-L error
SC690-03
D
Communication between CRB-L and IOB error