1.SC Codes
144
Error Name/Error Condition/Major Cause/Solution
-03: Communication error between the CRB-L and IOB
Harness between CRB and IOB defective/disconnected/shorted
CRB-L defective
IOB defective
1. Reconnect the harness between CRB-L and IOB.
2. Replace the harness between CRB-L and IOB.
3. Replace the CRB-L.
4. Replace the IOB.
Error Name/Error Condition/Major Cause/Solution
No interruption from the IOB (during communication or position detection)
Harness between CRB and IOB defective/disconnected/shorted
CRB-L defective
IOB defective
1. Reconnect the harness between CRB and IOB.
2. Replace the harness between CRB and IOB.
3. Reconnect or replace the harnesses to the parts listed below:
CRB-L
IOB
SSB
Cooling unit exit sensor
Exit JG sensor
Measuring roller encoder sensors 1/2
4. Replace the sensors/encoders listed below:
Cooling unit exit sensor
Exit JG sensor
Measuring roller encoder sensors 1/2
5. Replace the CRB-L/SSB.
6. Replace the IOB.
Error Name/Error Condition/Major Cause/Solution
TIM-Mag error 1: after fusing: serial communication error: IPAC2
TIM-Mag error 1: after fusing: PLL error: CANOPUS
TIM-Mag error 1: after fusing: PLL error: REGOR