1.SC Codes
172
Error Name/Error Condition/Major Cause/Solution
Partner terminal does not break even 200 msec after the downstream device
starts to wait.
ATN without break is received in advance from the downstream device.
ST2 is received from the downstream device during receipt of ST1 frame, or
vice versa.
When the response (ACKn) to the frame sent to the downstream device is not
notified within the time limit (100 msec), frame sending is retried a maximum
of 3 times but there is still no responses acquired.
After connection with the downstream device, the downstream device breaks
again.
Interface cable (downstream device side) connector disconnected or broken
PCB of downstream device defective
Controller PCB defective
Replace the interface cable.
Replace the PCB of downstream device.
Replace the controller board.
Error Name/Error Condition/Major Cause/Solution
Multi-Folding Unit: Protection device break error 1
A fuse has blown on the 24V1 line.
Error Name/Error Condition/Major Cause/Solution
Multi-Folding Unit: Protection device break error 2
A fuse has blown on the 24V2 line.
Error Name/Error Condition/Major Cause/Solution
Registration Roller Transport Motor Error
Motor driver detected an error. (SC from the first time)
Overcurrent to the motor.
Replace the Main Board.
Replace the Registration Roller Transport Motor.
Replace the harness.