1.SC Codes
174
Error Name/Error Condition/Major Cause/Solution
specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after
specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
Overcurrent to the motor.
Motor drive overheat
Connector disconnected
Replace the Main Board.
Replace the Stopper 2 Motor.
Replace the harness.
Reconnect the connector.
Replace the Stopper 2 HP Sensor.
Error Name/Error Condition/Major Cause/Solution
When moving to the home position, home position was not detected within
specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after
specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
Overcurrent to the motor.
Motor drive overheat
Connector disconnected
Replace the Main Board.
Replace the Stopper 3 Motor.
Replace the harness.
Reconnect the connector.
Replace the Stopper 3 HP Sensor.
Error Name/Error Condition/Major Cause/Solution
When moving to the home position, home position was not detected within
specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after
specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
Overcurrent to the motor.