1.SC Codes
195
Error Name/Error Condition/Major Cause/Solution
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Master EEPROM Read Error
Data written to the EEPROM does not match data read from the EEPROM
Replace the master control board EEPROM
Replace the master control board.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Master EEPROM write error
When data was written to the EEPROM, the EEPROM signaled that it was busy
for longer than 25 ms and did not recover.
Install the master control board EEPROM
Replace the master control board EEPROM
Replace the master control board.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Master-to-inserter initial communication error
After the ConfigSet (parallel signal) went ON while the inserter connection status
was being checked, the initialization did not end successfully within 5 sec.
Inserter board defective
Connector loose, broken, defective
Reconnect the connector.
Replace the master control board.
Replace the inserter board.
Replace the harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Master-to-Inserter Board Communication Error
No response to the specified command during the timeout. There was an overflow
in memory where information required for paper feed is stored. (Master control
board detection.)
Communication error at inserter
Connector loose, broken, defective