1.SC Codes
196
Error Name/Error Condition/Major Cause/Solution
Reconnect the connector.
Replace the master control board.
Replace the inserter board.
Replace the harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Software matching error
The IDs for the relay software of the master, slave, cutter, inserter devices do not
match.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: 24V Check Signal Error 1
The 24V1 monitor signal of the master control board did not go off even though
the front door switch was closed.
(Relay circuit failed to go ON.)
Front door L/R SW defective
Master control board defective.
Reconnect the connector.
Replace the front door L/R SW.
Replace the master control board.
Replace the sensor harness
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: 24V Check Signal Error 2
Top cover switch open or the 24V2 monitoring signal of master controller lost
power for more than 5 sec, regardless of the status of the front door L/RWS and
top cover sensor.
(Top cover sensor, or top cover switch is faulty.)
Front door L/RSW defective
Top cover switch defective
Top cover sensor defective
Master board defective
Reconnect the connector.
Replace the front door L/RSW.
Replace the top cover switch