1.SC Codes
197
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
Replace the top cover sensor.
Replace the master control board.
Replace the sensor harness.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC750-
22
D
Perfect Binder: 24V Check Signal Error 3
The 24V2 check signal of the slave control board failed to go OFF within 5 sec.
even though the front door and top cover are closed.
Front door L/RSW defective
Top cover switch defective
Top cover sensor defective
Master board defective
Reconnect the connector.
Replace the front door L/RSW.
Replace the Top cover switch
Replace the topcover sensor.
Replace the slave board.
Replace the sensor harness.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC750-
23
D
Perfect Binder: 24V Check Signal Error 4
The 24V3 check signal of the slave control board failed to go OFF within 5 sec.,
regardless of the status of the front door (monitored by the master control board).
Front door L/RSW defective
Slave Control Board defective
Reconnect the connector.
Replace the front door L/RSW
Replace the slave board.
Replace the sensor harness.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC750-
24
D
Perfect Binder: Power supply fan (right) lock error
Right power supply fan failed to generate a lock signal within 12 sec., and signal
could be detected even after a re-try.
Right power supply fan overloaded, defective
Slave Control Board defective
Reconnect the connector.