2. If SC499 (intermediate transfer control error) has occurred, take the
appropriate measure.
3. Clean/Replace the ITB.
4. Clean/Replace the TM/ID sensor.
5. Execute SP2-154-050: MUSIC Setting: 2 Patch Pos Adjust. (Adjust the
position of the MUSIC pattern with respect to the TM/ID sensor.)