1.SC Codes
355
Error Name/Error Condition/Major Cause/Solution
Replace the connector
Reconnect the connector
Replace the board
Error Name/Error Condition/Major Cause/Solution
Ring Binder: Jogger fence 2 error
When moving to the home position, the sensor could not detect the
component at the home position within the prescribed time (400 pulses). The
first occurrence triggers a jam, the second an SC code.
The sensor failed to detect that the component had moved out of the home
position within the prescribed time (400 ms). The first occurrence triggers a
jam, the second an SC code.
Jog fence 2 motor (M606) defective
Connector loose, broken, defective
Motor overload
Side fence 2 HP sensor (S611) defective
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
Error Name/Error Condition/Major Cause/Solution
Ring Binder: Stack tamper HP error
When moving to the home position, the sensor could not detect the
component at the home position within the prescribed time (400 pulses). The
first occurrence triggers a jam, the second an SC code.
The sensor failed to detect that the component had moved out of the home
position within the prescribed time (400 ms). The first occurrence triggers a
jam, the second an SC code.
Stack tamper motor (M607) defective
Motor overloaded
Connector loose, broken, defective
Stack tamper HP sensor (S612) defective