1.SC Codes
359
Error Name/Error Condition/Major Cause/Solution
1500 ms (1st detection signals a jam, 2nd detection issues this SC code)
Clamp unit motor (M701) defective
Connector loose, broken, defective
Motor overload
Bind timing sensor (S702) defective
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
Error Name/Error Condition/Major Cause/Solution
Ring Binder: Clamp unit HP error
At initialization or during ring binding, the unit did not arrive at home position
within the prescribed time (1500 ms) (1st detection triggers a jam alert, 2nd
detection issues this SC code).
The sensor failed to detect that the component had moved out of the home
position within the prescribed time (1500 ms) (1st detection triggers a jam
alert, 2nd detection issues this SC code).
Clamp unit motor (M701) defective
Connector loose, broken, defective
Motor overload
Clamp unit HP sensor (S701) defective
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
Error Name/Error Condition/Major Cause/Solution
Ring Binder: Spine alignment error
During alignment a home position timeout (400 ms) occurred twice during
movement of the tip of the alignment pin (2nd attempt was within an additional 400
ms).
Alignment pin motor (M602) defective
Connector loose, broken, defective
Alignment pin HP sensor (S604) defective