1.SC Codes
361
Error Name/Error Condition/Major Cause/Solution
The sensor failed to detect that the component had moved out of the home
position within the prescribed time (200 pulses). The first occurrence triggers
a jam, the second an SC code.
The sensor could not detect the component within the prescribed time (2125
pulses). The first occurrence triggers a jam, the second an SC code.
Output belt 1 motor (M401) defective
Connector loose, broken, defective
Motor overload
Output belt 1 HP sensor (S401) defective
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
Error Name/Error Condition/Major Cause/Solution
Ring Binder: Output belt 2 HP error
The sensor failed to detect that the component had moved out of the home
position within the prescribed time (200 pulses). The first occurrence triggers
a jam, the second an SC code.
The sensor could not detect the component within the prescribed time (3130
pulses). The first occurrence triggers a jam, the second an SC code.
Output belt 2 motor (M402) defective
Connector loose, broken, defective
Motor overload
Output belt 2 HP sensor (S402) defective
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
Error Name/Error Condition/Major Cause/Solution
Ring Binder: Stack height error
The height of the stack increases until the stack height sensor goes ON. The
sensor did not go ON within 6 sec. after the motor went ON (1st detection triggers
a jam alert, 2nd detection issues this SC code).