1.SC Codes
363
Error Name/Error Condition/Major Cause/Solution
PCB defective
Poor grounding of the 24V line
Reconnect the connector on the harness between PSU and PCB on LCT1.
Replace the harness
Replace the PSU.
Replace the PCB.
Replace the harness/actuator.
Error Name/Error Condition/Major Cause/Solution
LCT1: PSU Cooling Fan 1 error
Cooling fan alarm “H (error)” is detected while the PSU Cooling Fan 1 on the
LCT1 is ON.
PSU Cooling Fan 1 on the LCT1 defective
Connector disconnected
Harness broken
PSU defective
PCB defective
Reconnect the connector.
Replace the PSU Cooling Fan 1 on the LCT1.
Replace the harness
Replace the PSU.
Replace the PCB.
Error Name/Error Condition/Major Cause/Solution
LCT1: PSU Cooling Fan 2 error
Cooling fan alarm “H (error)” is detected while the PSU Cooling Fan 2 on the
LCT1 is ON.
PSU Cooling Fan 2 on the LCT1 defective
Connector disconnected
Harness broken
PSU defective
PCB defective
Reconnect the connector.
Replace the PSU Cooling Fan 2 on the LCT1.
Replace the harness
Replace the PSU.