1.SC Codes
364
Error Name/Error Condition/Major Cause/Solution
Error Name/Error Condition/Major Cause/Solution
LCT1: Bridge Unit Cooling Fan error
Cooling fan alarm “H (error)” is detected while the cooling fan on the bridge unit
of LCT1 is ON.
Cooling fan defective
Connector disconnected
Harness broken
PCB on the LCT1 defective
Reconnect the connector.
Replace the cooling fan.
Replace the harness
Replace the PCB on the LCT1.
Error Name/Error Condition/Major Cause/Solution
LCT1: Transport Motor Cooling Fan error
Cooling fan alarm “H (error)” is detected while the Transport Motor Cooling Fan
on the LCT1 is ON.
Transport Motor Cooling Fan on the LCT1 defective
Connector disconnected
Harness broken
PCB defective
Reconnect the connector.
Replace the Transport Motor Cooling Fan on the LCT1.
Replace the harness
Replace the PCB.
Error Name/Error Condition/Major Cause/Solution
LCT1: Transport Motor Cooling Fan error
Cooling fan alarm “H (error)” is detected while the Transport Motor Cooling Fan
on the LCT1 is ON.
Transport Motor Cooling Fan on the LCT1 defective
Connector disconnected
Harness broken
PCB defective
Reconnect the connector.